Solvents, fuels, paints and thinners

Flammable liquid storage and DSEAR

The liquid is rarely the problem. The vapour above it is, and vapour goes where the ventilation sends it.

Flash point is what decides the risk

A liquid gives off vapour continuously. Whether that vapour can form an explosive atmosphere at the temperature your workshop actually runs at is what the flash point tells you. Something with a flash point below ambient is producing an ignitable mixture in the headspace of the drum all day, every day, without anybody doing anything.

That is why the safety data sheet is the first thing we ask for, and why an assessment based on what the labels say rather than on what the sheets say is not worth much.

What we look at

Containers and closure

Whether drums, IBCs and jerry cans are closed when not in use, and whether the ones in daily use ever actually get closed.

Decanting

The single highest-risk operation on most sites. Bonding and earthing, plastic containers, funnels, and where the displaced vapour goes.

Ventilation

Natural or mechanical, high and low level, and whether it still works now the racking has been moved in front of it.

Spill containment

Bunding, drainage, and what would happen to a full IBC failing at four in the afternoon.

Ignition sources

Electrical fittings inside the store, forklifts driving through, hot work, static, and mobile phones carried in by contractors.

Separation

Distance from boundaries, occupied buildings and other stored substances, especially oxidisers.

Questions

How much can I store before DSEAR applies?

There is no threshold. DSEAR applies as soon as a dangerous substance is present at work. Separate storage quantity limits do exist in guidance for what may be kept in a workroom, but they are about good practice, not about whether you need an assessment.

Do I need a bund?

If a spill could reach a drain, a watercourse or an ignition source, almost certainly. The usual benchmark is retention of 110 percent of the largest container, and on the Milford Haven Waterway the environmental consequences of getting it wrong are taken seriously.

Is my flammables cabinet enough?

A cabinet controls a small quantity in a workroom. It does not remove the need for an assessment, and it does nothing about the vapour released when someone decants at the bench next to it.

What zoning will I end up with?

It depends on the release sources and the ventilation. A well-ventilated external store with closed containers often ends up with a small Zone 2 around vents and fill points. An unventilated internal decanting room can be considerably worse.

Related

Hazardous area classification

How the zones around a store and its vents are worked out.

ATEX equipment

What can legally be installed once a zone exists.

What it costs

Fixed price, quoted after a short scoping call.

Tell us what you store and we'll tell you where you stand

No charge for the conversation. Most quotes go out the same day.